Woodpecker TFRK Terauchi File Removal Kit
The Woodpecker TFRK Terauchi File Removal Kit is a specialized dental instrument designed for the removal of broken or separated endodontic files from within the root canals of teeth. This kit is a valuable tool in endodontics, where maintaining the integrity of the root canal during treatment is crucial.
TFRK-Gutta-Percha Removal Hand Instrument (TFRK-GPR)
- Made of stainless steel, 4% taper
- Can be pre-curved to fit the canal curvature
- With delta cones (max. diameter: 0.35mm) on both end
- Used for the removal of filling material remnants and for the removal of necrotic pulp tissues or debris in a narrow space. Smaller-sized pyramidal tips can make it very easy to scrape gutta-percha root fillings from the canal wall.
TFRK-Micro-Explorer (TFRK-ME)
Made of stainless steel, a sharp 0.1 mm-tip-diameter explorer, double-ended, 6% taper, smooth-surfaced. The TFRK-ME has extremely fine spear-shaped tips with a smooth surface for by passing ledged canals and exploring the canal for broken files or other impediments. This instrument can be bent to meet the canal curvature so that the TFRK tips can be precurved the same way as it is before use. When there is a ledge formed coronal to the separated file in the canal, the TFRK-ME can be used to locate the original canal and the ledge can be reduced by using it with several push-pull strokes.
TFRK-Micro-Trephine bur (TFRK-MT)
The inner diameter of the MT is ∅0.5mm whereas the outer diameter of the MT is 0.8 mm.
TFRK-MT can be used when the canal curvature is <15° and the coronal diameter of the broken file is 0.45 mm. The inner depth of the MT is 1 mm to expose a 1 mm portion of the broken file. Spin the MT at 600 rpm counterclockwise in a short in/out motion to expose the coronal 1 mm portion of the broken file after the canal enlargement with the MGG #3 rotating at 2500 rpm to the broken file. If the canal curvature is > 15°, a size # 60/.02 taper flexible NiTi rotary file should be used to enlarge the canal to the broken file.
Modified Gates Glidden Drill #3 (MGG #3)
The pilot tip of the Gate Glidden Drill #3 is cut off so that the root canal to the broken file can be enlarged to at least 0.45 mm as the tip diameter of the MGG #3 is 0.45 mm. It is used at 2500 rpm clockwise with a brushing motion against the outer wall to create a funnel shape.
Martensitic-phased NiTi Rotary Instrument K-Endo (K6 N60 2% L25)
60%, 2% taper, NiTi file in the martensitic phase at 37°C If the coronal diameter of the broken file is >0.45 mm or the canal curvature is > 15°, use this rotary instrument to enlarge the canal to the broken file at 500 rpm counterclockwise.
Broken File Removal Tips (E87, E88, E89) TFRK-Katana Vertical (TFRK-Katana V or E88)TFRK- KatanaHorizontal (TFRK-Katana H or E89)
TFRK-Katana V/H is designed with an extremely thin sword-shaped tip to create a 90-degree
semicircular ditch on the inner wall of the broken file. They can be pre-curved to be adapted to the canal curvature. Activate ultrasonics with the flat surface directed to the broken file from the inner wall of the canal. Feature: Create a 90°semicircular grooved space.
TFRK-Straight (TFRK-S or E87)
TFRK-S is characterized by an extremely sharp cone-shaped tip: 0.1 mm diameter tip with 1% taper that can be pre-curved to be adapted to the canal curvature.
- Feature 1: Extend the grooved space to a 180°semicircular ditch until the broken
file is seen dancing after the 90° semicircular space created on the inner wall with the Katana V/H. - Feature 2: Remove the broken File
- Feature 3: Create a thin space between the canal wall and gutta-percha root fillings. for the introduction of the TFRK-GPR
- Feature 4: Remove necrotic pulp tissues and debris from an isthmus or a thin space.
TFRK-Loop (TFRK-L: Yoshi Loop)
Used to retrieve the broken file after loosening it in preparation with ultrasonics when the broken file is longer than 4.5 mm or the broken file did not come out with ultrasonics in 10 seconds removal attempts. The loop size is adjusted to the diameter of the broken file with an endodontic explorer and bent to 45 degrees to facilitate the placement of the loop over the broken file. The loop cannula is replaceable. The damaged loop can be quickly and easily replaced with a new loop. There are two sizes of the loop wire: 0.12 mm and 0.08 mm, suitable for different clinical situations with varying root canal diameters and resistance.
The maximum diameter of the microtube holding the loop is 0.5 mm and it has a 23 mm length. The microtube can be pre-curved to facilitate its placement into the root canal.
Brownie Polishing Point (TFRK-P)
A silicone rubber-based tool used with a straight handpiece. It is designed for sharpening
ultrasonic tips to the desired shape and can also be used for polishing to enhance sharpness.
Features
- Comprehensive Instrumentation: The kit includes a variety of specialized instruments designed for different aspects of broken or separated file removal, offering versatility in addressing a wide range of clinical scenarios.
- Precision and Durability: All instruments are made of high-quality stainless steel, ensuring precision and durability during use.
- Adaptability: Several instruments in the kit can be pre-curved to match the canal curvature, enhancing their adaptability for specific cases.
- Efficient Broken File Removal: The kit provides tools to create grooved spaces, reduce ledges, and retrieve broken files with efficiency and precision.
- Safe and Effective: Designed to ensure the safety of the root canal and surrounding tissues while effectively addressing the challenges of broken files.
- Adjustable Loop Design: The TFRK-Loop (Yoshi Loop) is equipped with an adjustable and replaceable loop, suitable for different root canal diameters and scenarios, providing a versatile solution for retrieving broken files.
- Sharpening and Polishing: The Brownie Polishing Point (TFRK-P) offers the added benefit of sharpening ultrasonic tips and polishing to enhance their performance.
- Clinical Flexibility: With a diverse set of instruments, the kit provides the flexibility needed to address various clinical situations during endodontic procedures.
- Enhanced Success: By facilitating the removal of broken files and ensuring the preservation of the tooth’s integrity, the kit contributes to the overall success of complex endodontic treatments.
- Quality Assurance: The Woodpecker brand is known for its commitment to quality and innovation, providing dental professionals with reliable and effective tools for their practice.
key Specifications
- Material: Stainless Steel
Dimensions:
- TFRK-GPR: Both side tips size 30mm
- TFRK-ME: Both side tips size 30mm
- TFRK-MT: Inner diameter ∅0.5mm, Outer diameter 0.8 mm,Length 25.8mm
- K-Endo (K6 N60 2% L25): ∅0.6mm, Length 25mm
- MGG #3: ∅0.9mm
- TFRK-Katana V (E88): ∅0.3mm,∅0.1mm,Length 25.3mm
- TFRK-Katana H (E89): ∅0.3mm,∅0.1mm,Length 25.3mm
- TFRK-Straight (E87): ∅0.1mm,Length 25.3mm
- TFRK-Loop: ∅0.5mm,Length 123mm
- TFRK-P: ∅5mm,Length 16mm
- 1 x Dental Explorer TFRK-GPR
- 1 x Dental Explorer TFRK-ME
- 1 x Endo File Remover TFRK-L
- 1 x Ultrasonic Scaler Tip (Endodontics) E87
- 1 x Ultrasonic Scaler Tip (Endodontics) E88
- 1 x Ultrasonic Scaler Tip (Endodontics) E89
- 1 x Polishing Rod TFRK-P
- 1 x Gate Drill #3
- 1 x Trephine TFRK-MT
- 1 x K Endo K6 N60 2% L25
- 1 x Autoclavable Cassette
- 1 x Instruction Manual
Reviews
There are no reviews yet.